Home » Bộ điều khiển ENet 1769-L33ER CompactLogix 2 MB
PRODUCT

Bộ điều khiển ENet 1769-L33ER CompactLogix 2 MB

Product Overview – Detailed Description

Part Number: 1769-L33ER

Model 1769-L33ER
User memory
1 MB
Optional nonvolatile memory

 

1784-SD1 card with 1 Gb of available memory (shipped with controller)
1784-SD2 card with 2 Gb of available memory (available for separate ordering)
Number of local expansion modules, max¹ Eight 1769 Compact I/O modules
Number of I/O module banks, max 3
Current draw @ 5V DC, controller power 500 mA
Current draw @ 24V DC, controller power 225 mA
Current draw @ 24V DC, field power, max N/A
Power dissipation, max 4.5 W.
Isolation voltage

 

30V (continuous), Basic Insulation Type, USB to system, Ethernet to system and Ethernet to Ethernet
Type tested at 500V AC for 60 s
Short circuit protection, field power N/A
Recommended external short circuit protection, field power N/A
Weight, approx 0.31 kg (0.68 lb)
Module width 55.00 mm (2.17 in.)
Module location DIN rail or panel mount
Panel-mounting screw torque 1.1 1.8 N m (10 16 lb in) – use M4 or #8 screws
Embedded power supply 1769-PA2, 1769-PB2, 1769-PA4, 1769-PB4
Power supply distance rating Controller and 1769-SDN: 4
1769 Compact I/O modules: 4 8, depending on module
Wire category² 2 – communication ports
Wire type, Ethernet
RJ-45 connector according to IEC 60603-7, 2 or 4 pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702
Wire type, power terminals and embedded I/O connections N/A
Wire size, power terminals³ N/A
Wire stripping length, power terminals³ N/A
Screw torque, power terminals³ N/A
Wire size, embedded I/O connections N/A
Wire stripping length, embedded I/O connections N/A
North American temperature code T5
IEC temperature code T5
Enclosure type rating None (open-style)

(1) You can use up to the maximum number of local expansion modules with the CompactLogix 5370 L1 controllers that are listed as long as the total current drawn by the embedded

I/O and local expansion modules does not exceed both the available POINTBus backplane current of 1 A and the field power current of 3 A.

(2) Use this Conductor Category information for planning conductor routing.

(3) Regarding the CompactLogix 5370 L1 controllers, this specification applies to connecting wires to the power connector that is inserted in the controller.

 

Please contact Nam Tien Thinh  – Hotline: 091.9999.010 to get technical support and the best price.

Key Features & Outstanding Advantages

Add items in repeater uu_diem_noi_bat.

Applications – Where It Performs Best

Technical Specifications – 100% Fields

Documentation & Media

Ecosystem & Cross-Links

◍ Reference Projects
READY TO AUTOMATE?
Need a tailored palletizing cell?
Let's engineer it together.
Our engineers deliver turnkey – robot, gripper, safety, PLC, commissioning. 48h quotation. 12-month implementation support.
Yêu cầu báo giá